A fix is available
APAR status
Closed as program error.
Error description
In some situations, the reloading of dynamically loaded modules may result in an ABEND 0C4. The ABEND is caused by a bad DCB resulting from the previously dynamically loaded modules. Properly unloading the modules results in a correct DCB the next attempt at dynamically loading the modules. The problem may be indicated by an ABEND S0112 - "AB/S0112 System abend code: 0112"
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Security Guardium S-TAP for * * Db2 on z/OS. * * * **************************************************************** * PROBLEM DESCRIPTION: In some situations, the reloading of * * dynamically loaded modules may result * * in an ABEND 0C4. The ABEND is caused by * * a bad DCB resulting from the * * previously dynamically loaded modules. * * Properly unloading the modules results * * in a correct DCB the next attempt at * * dynamically loading the modules. * * The problem may be indicated by an * * ABEND S0112 - "AB/S0112 System abend * * code: 0112" * * * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Properly unload dynamically loaded modules when not in use.
Problem conclusion
Unloading of dynamically loaded modules resolves underlying ABEND 112 reported by Changeman intercepts setup on LOAD SVC.
Temporary fix
Comments
APAR Information
APAR number
PH66195
Reported component name
SEC GUAR STAP D
Reported component ID
5655STP00
Reported release
B30
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-04-18
Closed date
2025-05-05
Last modified date
2025-05-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO03044
Modules/Macros
ADHPDB2C
Fix information
Fixed component name
SEC GUAR STAP D
Fixed component ID
5655STP00
Applicable component levels
RB30 PSY UO03044
UP25/05/08 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B30","Line of Business":{"code":"LOB76","label":"Data Platform"}}]
Document Information
Modified date: