PH66131: THE FPA UNLOAD/CHANGE JOB THAT INCREASES THE MAXIMUM LENGTH OF THE SDEP FAILS WITH HFPC0062E

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the SDEP=PHYSICAL keyword is specified and the RELOCATE_SDEP=
    keyword is omitted, the FPA UNLOAD/CHANGE job that increases the
    maximum length of the SDEP fails with error MSGHFPC0062E.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool   *
    *                 in Fast Path Solution Pack Version 2         *
    *                 Release 1 (FMID: HAHQ210).                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: If the SDEP=PHYSICAL is specified and   *
    *                      the RELOCATE_SDEP keyword is omitted    *
    *                      when increasing the maximum length of   *
    *                      variable-length SDEP, FPA               *
    *                      UNLOAD/CHANGE functions issue           *
    *                      HFPC0062E incorrectly.                  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    FPA UNLOAD/CHANGE functions set RELOCATE_SDEP value incorrectly
    when the SDEP=PHYSICAL is specified and the RELOCATE_SDEP
    keyword is omitted, which cause these functions to issue
    HFPC0062E incorrectly when increasing the maximum length of
    variable-length SDEP.
    

Problem conclusion

  • FPA has been modified to set the RELOCATE_SDEP value correctly
    when the RELOCATE_SDEP keyword is omitted.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH66131

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-04-14

  • Closed date

    2025-05-29

  • Last modified date

    2025-05-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO03413

Modules/Macros

  • HFPCDST0 HFPCDSU0 HFPCSUP0 HFPUMVT0 HFPWMTU0
    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R210 PSY UO03413

       UP25/05/30 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]

Document Information

Modified date: