A fix is available
APAR status
Closed as program error.
Error description
If the SDEP=PHYSICAL keyword is specified and the RELOCATE_SDEP= keyword is omitted, the FPA UNLOAD/CHANGE job that increases the maximum length of the SDEP fails with error MSGHFPC0062E.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool * * in Fast Path Solution Pack Version 2 * * Release 1 (FMID: HAHQ210). * **************************************************************** * PROBLEM DESCRIPTION: If the SDEP=PHYSICAL is specified and * * the RELOCATE_SDEP keyword is omitted * * when increasing the maximum length of * * variable-length SDEP, FPA * * UNLOAD/CHANGE functions issue * * HFPC0062E incorrectly. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** FPA UNLOAD/CHANGE functions set RELOCATE_SDEP value incorrectly when the SDEP=PHYSICAL is specified and the RELOCATE_SDEP keyword is omitted, which cause these functions to issue HFPC0062E incorrectly when increasing the maximum length of variable-length SDEP.
Problem conclusion
FPA has been modified to set the RELOCATE_SDEP value correctly when the RELOCATE_SDEP keyword is omitted.
Temporary fix
Comments
APAR Information
APAR number
PH66131
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-04-14
Closed date
2025-05-29
Last modified date
2025-05-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO03413
Modules/Macros
HFPCDST0 HFPCDSU0 HFPCSUP0 HFPUMVT0 HFPWMTU0
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R210 PSY UO03413
UP25/05/30 I 1000
Fix is available