A fix is available
APAR status
Closed as program error.
Error description
When the BASE portion of an AREA is more than 2GB, and Image Copy data set is used as input, FPA obtains two data spaces to copy the IC records. At that time, if the IC data set is compressed or ICINCOMP=YES is specified and no IC records are stored in the second data space, the FPA job ends abnormally with an ABENDU3054.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool * * in Fast Path Solution Pack Version 2 * * Release 1 (FMID: HAHQ210). * **************************************************************** * PROBLEM DESCRIPTION: FPA job abended with U3054 when * * the compressed IC records are not * * stored in the second data space. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR * **************************************************************** When the BASE portion of an area is more than 2GB, and Image Copy data set is used as input, the FPA obtains two data spaces to copy the IC records. At that time, if the IC data set is compressed or ICINCOMP=YES is specified and no IC records are stored in the second data space, the FPA job ends abnormally with U3054.
Problem conclusion
FPA has been modified to not access the second data space if the IC records were not stored in the second data space.
Temporary fix
Comments
APAR Information
APAR number
PH66114
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-04-11
Closed date
2025-05-02
Last modified date
2025-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO03025
Modules/Macros
HFPVICI0
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R210 PSY UO03025
UP25/05/03 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date: