IBM Support

PH65458: COLLATOR ZFILE CLOSING PROCESS ENHANCEMENTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1. Collator stops without closing any files if it encounters
    a problem.
    
    2. Collator closes the old file 20 minutes after
       the maximum number of records has been written to the file.
    
    3. The user is unable to change the time the Collator keeps
       the files open for output.
    
    4. SMF subtype values are parsed incorrectly for some
       SMF records.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of                                 *
    *                 IBM Z Performance and Capacity Analytics     *
    *                 3.1.0.                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Collator stops without closing       *
    *                         any files if it encounters           *
    *                         a problem.                           *
    *                      2. Collator closes the old file         *
    *                         20 minutes after the maximum number  *
    *                         of the records has been written to   *
    *                         the file.                            *
    *                      3. The user is unable to change         *
    *                         the time the Collator keeps          *
    *                         the files open for output.           *
    *                      4. SMF subtype values are parsed        *
    *                         incorrectly for some SMF records.    *
    ****************************************************************
    * RECOMMENDATION: Apply the PTFs provided.                     *
    ****************************************************************
    1. When the Collator's output process fails and stops,
       it does not close files.
    2. When a new file is created because the old file reaches
       the maximum number of records, the Collator closes
       the old file 20 minutes later.
    3. Collator does not have a setting to adjust the wait timer
       for closing files.
    4. SMF subtype is incorrectly parsed for SMF records
       with non-standard subtypes.
    

Problem conclusion

  • 1. Collator closes all files when it fails and stops.
    2. Collator closes the old file immediately when a new file
       is created.
    3. The user can set the wait time using a parameter
       in the configuration file.
    4. Subtypes are ignored for SMF records that do not have them.
       SMF records 60, 61, 65 and 66 have their textual subtypes
       mapped to numeric values.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH65458

  • Reported component name

    TDS FOR Z/OS

  • Reported component ID

    569510100

  • Reported release

    C01

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-02-27

  • Closed date

    2025-03-28

  • Last modified date

    2025-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO02611 UO02612 UO02613

Modules/Macros

  • DRLDOD72 DRLPJCO  DRLPJDI  DRLPJDM  DRLPJDS  DRLPJFC  DRLPJSD
    DRLPJSM
    

Fix information

  • Fixed component name

    TDS FOR Z/OS

  • Fixed component ID

    569510100

Applicable component levels

  • RC01 PSY UO02611

       UP25/04/10 P F504

  • RCA0 PSY UO02612

       UP25/04/10 P F504

  • RCA8 PSY UO02613

       UP25/04/10 P F504

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C01","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
02 May 2025