A fix is available
APAR status
Closed as program error.
Error description
Performance Analyzer SYSTEM COMPLETION CODE=0CC REASON CODE=0000000C encountered due to a change made by APAR PH60661 which provided a new derived field for CICS PA, but CICS PA didn't handle negative STCK elapse time well, thus causing this issue. The field causing the "bad SMF110" record which CICS PA is not handling correctly was: ( Field = DSGTDT, Domain = DS, Stats ID = 062, Macro = DFHDSGDS, DSECT = DSGTCBM )
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS PA 5.4 * **************************************************************** * PROBLEM DESCRIPTION: System completion code=0CC and reason * * code=0000000C when running CICS PA * * batch statistics reports or performing * * online browsing of statistics. * **************************************************************** A new derived field introduced by for APAR PH60661 caused CICS PA to not handle a negative STCK elapsed time correctly when performing the field calculation.
Problem conclusion
CICS PA has been changed to handle a negative STCK elapse time correctly when performing the field calculation.
Temporary fix
Comments
APAR Information
APAR number
PH65374
Reported component name
CICS PERF ANALY
Reported component ID
5655Y2300
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-02-21
Closed date
2025-03-18
Last modified date
2025-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO02483
Modules/Macros
CPASLSMF CPASMDS1 CPASMDS2 CPASMDS3 CPASMDS4 CPASMDS5 CPASMDS7 CPASMDS8 CPASMDSC CPASSMMF
Fix information
Fixed component name
CICS PERF ANALY
Fixed component ID
5655Y2300
Applicable component levels
R540 PSY UO02483
UP25/03/25 P F503
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPPU4","label":"CICS Performance Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 April 2025