A fix is available
APAR status
Closed as program error.
Error description
IMS Hangs following "SETXCF START,REALLOCATE" command while rebuilding OSAMCACHE structure in Coupling Facility. This problem only occurs when ZAD/PRIMEPSA (IGVDGNPP) is enabled. The following error is seen following this command: "IXL040E CONNECTOR NAME: IXCLO0C30002, JOBNAME: dlisas, ASID: xxxx nnn HAS NOT RESPONDED TO THE REBUILD QUIESCE EVENT. REBUILD PROCESSING FOR STRUCTURE OSAMCACHEx CANNOT CONTINUE."
Local fix
Run without ZAD/PRIMEPSA (IGVDGNPP) enabled
Problem summary
**************************************************************** * USERS AFFECTED: * * ALL IMS V15 Full Function users using the Coupling Facility * * and the z/OS tool IGVDGNPP ( PRIMEPSA ) * **************************************************************** * PROBLEM DESCRIPTION: * * IMS hangs after issuing command "SETXCF START,REALLOCATE" * * while rebuilding the OSAMCACHE structure in the Coupling * * Facility. This problem only occurs when ZAD/IGVDGNPP ( * * PRIMEPSA ) is enabled. * * * * The following error is seen after issuing the SETXCF * * command: "IXL040E CONNECTOR NAME: IXCLO0C30002, JOBNAME: * * dlisas, ASID: xxxx nnn HAS NOT RESPONDED TO THE REBUILD * * QUIESCE EVENT. REBUILD PROCESSING FOR STRUCTURE OSAMCACHEx * * CANNOT CONTINUE." * **************************************************************** * RECOMMENDATION: * * INSTALL CORRECTIVE SERVICE FOR APAR/PTF. * **************************************************************** With IGVDGNPP enabled, the low core values will not equal to zero, then the code in module DFSDVSM0 after label UPAD1250 will fall through to the DFSDXFEN macro call. Register 4 will equal to zero causing low core to be accessed and the test for flag BUFCBSYR in IDABUFC will not be equal to zero. When macro DFSDXFEN is called inappropriately, then SCDVXCNT will unconditionally be decremented to less than zero. With SCDVXCNT never equal to zero and waiting in module DFSDCFR0 subroutine RBLDQSE after having checked the SCDVXCNT and SCDOXCNT fields for zero. Since the count field will not be equal to zero the wait will never get posted and IMS will hang.
Problem conclusion
Code is added in module DFSDVSM0 after label UPAD1250 to check the BUFC address ( UPABUFC ) for zero. If zero, branch to label UPAD2000 to skip the DFSDXFEN macro call.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PH65016
Reported component name
IMS V15
Reported component ID
5635A0600
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-01-28
Closed date
2025-09-09
Last modified date
2025-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO04817
Modules/Macros
DFSDVSM0
Fix information
Fixed component name
IMS V15
Fixed component ID
5635A0600
Applicable component levels
R500 PSY UO04817
UP25/09/16 P F509 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSEPH2","label":"IMS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"15","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: