Error description
When compiling a program with multiple literals that are powers of 2, the optimizer transforms the program in a way that produces a faster compiled program but slows down the compiler when it does further optimizations.
Local fix
Compile at OPT(0) or ARCH(11) or substitute the literals with their product.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling * * programs at OPT(1|2),ARCH(12) that have * * multiply a data item by multiple literals, * * where each literal is a power of 2. * **************************************************************** * PROBLEM DESCRIPTION: Program takes an excessive time to * * compile. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** When compiling a program with multiple literals that are powers of 2, the optimizer transforms the program in a way that produces a faster compiled program but slows down the compiler when it does further optimizations.
Problem conclusion
The compiler was fixed to perform further optimizations more efficiently after it expands the multiplications.
Temporary fix
Comments
APAR Information
APAR number
PH64909
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-01-21
Closed date
2025-01-23
Last modified date
2025-02-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI99722
UP25/01/30 P F501
R631 PSY UI99723
UP25/01/30 P F501
R632 PSY UI99724
UP25/01/30 P F501
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
03 February 2025