Error description

  • GDPS Metro documentation indicates "For automation operators,
    define VPCCGEIC as the Initial Command". This is not correct
    for the AUTWEBUI operator, whose IC should be VPCUDMON.
    
    Also, some of the automation operator definitions supplied in
    the GEOOP* members have incorrect PROFILEN specifications.
    All GDPS operators should have PROFILEN GEOPRFAO, with the
    exception of AUTWEBUI which should have PROFILEN GEOPRFUI.
    
    In addition, some clients with OPERSEC SAFDEF configurations
    have requested that the GDPS documentation more clearly
    indicate the need to specify the proper GDPS Initial Command
    in the NetView segment of the SAF profiles for the GDPS
    automation operators.
    
    Failure to define the correct initial command for an operator
    can lead to unpredictable results. The operator may be unable
    to perform its expected function, or function completion may
    be delayed during critical periods, which could lead to severe
    problems such as replication failure or system outages.
    
    For GDPS release 4.6 see related APAR PH69251
    
    ADDITIONAL RELATED ENHANCEMENT
    
    This APAR will also provide a Monitor1 enhancement to check
    if GDPS automation operators have executed the correct initial
    command, and if a standard GDPS EMCS console has been assigned
    (for all operators) and activated (for critical operators).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All GDPS users                               *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect profiles and/or initial       *
    *                      commands may be used for GDPS           *
    *                      automation operators                    *
    *                                                              *
    ****************************************************************
    Some of the automation operator definitions supplied in
    the GEOOP* members have PROFILEN specifications that cause
    execution of initial commands other than those required by
    GDPS. Further, GDPS documentation needs clarification that
    installations with OPERSEC SAFDEF must define the proper GDPS
    initial command in SAF profiles for the automation operators.
    
    Failure to define the correct initial command for an operator
    can lead to unpredictable results. The operator may be unable
    to perform its expected function, or function completion may
    be delayed during critical periods, which could lead to severe
    problems such as replication failure or system outage.
    

Problem conclusion

Temporary fix

Comments

  • This PTF also provides a Monitor1 enhancement that will check
    if GDPS automation operators have executed the correct initial
    command and if a standard GDPS EMCS console has been assigned
    (for all operators) and activated (for critical operators).
    
    ACTION REQUIRED
    
    This PTF changes the GDPS-supplied GEOOP* operator definition
    members to ensure that all GDPS automation operators specify the
    name of the GDPS-supplied profile. Previously, only some of the
    operator definitions had this specification.
    
    The PTF also standardizes EMCS console names for GDPS automation
    operators. The application program identifier (APPLID) for the
    task is used as the console name. APPLID is the NetView domain
    ID appended with a 3-character hexadecimal suffix assigned by
    the NetView program.
    
    Take the opportunity prior to installing this PTF to check your
    local GDPS automation operator definitions. With the PTF
    applied, Monitor1 will check if the correct initial command was
    executed for each operator, and that the standard EMCS console
    names have been assigned and activated as appropriate.
    
    If your installation uses OPERSEC SAFDEF, ensure that the SAF
    profiles for all GDPS automation operators except AUTWEBUI
    specify VPCCGEIC for the Initial Command in the NetView segment
    of their SAF profiles. For AUTWEBUI (or its equivalent) specify
    VPCUDMON.
    
    If your installation uses an OPERSEC value other than SAFDEF,
    review your local DSIPARM members to ensure that the OPERATOR
    statements for all GDPS automation operators except AUTWEBUI
    specify PROFILEN GEOPRFAO. For AUTWEBUI (or its equivalent)
    specify PROFILEN GEOPRFUI.
    
    Once you've ensured that the GDPS automation operators for a
    NetView domain are correctly defined. install the PTF in the
    domain, and confirm that all phases of GDPS initialization
    complete successful. Look in SDF for any GEO324W, GEO327W or
    GEO328E alerts, and if any are found, identify and correct
    the underlying reported problems.
    
    Repeat this for all GDPS NetView domains in your installation.
    
    NEW MESSAGES
    
    Messages GEO320E, GEO321W, GEO322W, GEO323W, GEO324W, GEO325E,
    GEO326E, GEO327E, and GEO328E are added to the GDPS Messages
    and Codes Reference Guide (ZG24-6762). See DOC hold for details.
    
    DOCUMENTATION CHANGES
    
    Publications affected:
    ZG24-6755 ZG24-6756 ZG24-6757 ZG24-6761 ZG24-6763
    
    The Installation and Customization Guides for GDPS Metro,
    GDPS Metro HyperSwap Manager, GDPS Global - GM, GDPS Logical
    Corruption Protection Manager, and GDPS Continuous Availability
    are updated.
    
    Various topics are changed to provide clearer guidance on how
    to define operator profiles and to make it easier to identify
    which operators need to be defined.
    
    Please refer to the PH64641 entries in the Summary of Changes
    for the online documentation, which can be found using the
    following links to the IBM Documentation web site:
    
    4.7 Metro:    https://ibm.biz/Bdm9Fh
    4.7 Metro HM: https://ibm.biz/Bdm9Fu
    4.7 GM:       https://ibm.biz/Bdm9F9
    4.7 CA:       https://ibm.biz/Bdm9FT
    4.7 LCP:      https://ibm.biz/Bdm9Fk
    
    4.8 Metro:    https://ibm.biz/BdnXJJ
    4.8 Metro HM: https://ibm.biz/BdnXJA
    4.8 GM:       https://ibm.biz/BdnXJu
    4.8 CA:       https://ibm.biz/BdnXJ9
    4.8 LCP:      https://ibm.biz/BdnXJC
    
    KEYWORDS: GDPS/K
    
    ×**** PE25/12/31 FIX IN ERROR. SEE APAR PH69520  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PH64641

  • Reported component name

    GDPS

  • Reported component ID

    694235B00

  • Reported release

    470

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-12-23

  • Closed date

    2025-12-17

  • Last modified date

    2026-02-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO06307 UO06308 UO06310 UO06311

Modules/Macros

  • DSIGEO32 GEO32    GEOAUTAA GEOAUTAS GEOAUTGM GEOAUTHM GEOAUTMM
    GEOCME00 GEOCMEAA GEOCMEAS GEOOPFA1 GEOOPFAL GEOOPFG1 GEOOPFLO
    GEOOPFMT GEOOPGA1 GEOOPGAL GEOOPGG1 GEOOPGLO GEOOPGMT VPCAMON1
    VPCCGEI2 VPCCGEIC VPCCOPEM VPCCOPEX VPCECONS VPCEMON  VPCSGEI2
    VPCSGEIC VPCSMON1 VPCSOPEM VPCSOPEX VPCUDMON
    

Fix information

  • Fixed component name

    GDPS

  • Fixed component ID

    694235B00

Applicable component levels

  • R470 PSY UO06310

       UP25/12/18 P F512 ¢

  • R47B PSY UO06311

       UP25/12/18 P F512 ¢

  • R480 PSY UO06307

       UP25/12/18 P F512 ¢

  • R48B PSY UO06308

       UP25/12/18 P F512 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SSET85","label":"GDPS (Geographically Dispersed Parallel Sysplex)"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"470","Line of Business":{"code":"LOB66","label":"Technology Lifecycle Services"}}]

Document Information

Modified date:
19 February 2026