A fix is available
APAR status
Closed as program error.
Error description
Customer is attempting an Optim EXTRACT process using an AD containing a Partitioned Table.The Extract process invokes IBM HPU to unload from an individual Image copy dataset for each partition. During the Extract (unload) process IBM HPU ends with a Fatal Syntax Error. INZU015E UNLOAD TABLESPACE STATEMENT : UNEXPECTED KEYWORD INZU039E FATAL SYNTAX ERROR BEFORE LINE 2 COLUMN 18 INZU541I DISPLAY OF IMPLICIT PARAMETERS ACTIVATED IN DDN STDERR INZU366I UTILITY RETURN CODE 8 (REASON CODE 0x107a002)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Optim users attempting to perform an * * extract by invoking IBM HPU to unload from * * individual image copy datasets for a * * Partitioned table. * **************************************************************** * PROBLEM DESCRIPTION: See Error Description. * **************************************************************** * RECOMMENDATION: Apply this fix. * **************************************************************** Incorrect control card was generated by Optim in order to process the unload from Imagecopy dataset using HPU. This error occurs only when separate image copy datasets are available for each partition. Optim generates an incorrect control card similar to the one shown below: UNLOAD TABLESPACE DBNAME.PSTJSPBR DB2 NO PSTC* Instead, it should be something like this: UNLOAD TABLESPACE DBNAME.PSTJSPBR COPYDDN PSTC* DB2 NO
Problem conclusion
Optim processing has been corrected to handle the above mentioned scenario.
Temporary fix
Comments
APAR Information
APAR number
PH64534
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-12-11
Closed date
2024-12-20
Last modified date
2025-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI99510
Modules/Macros
FOPMDXTR
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI99510
UP24/12/24 P F412
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]
Document Information
Modified date:
02 January 2025