Error description
s878 abend may be received after memory leak after encountering many exceptions.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 5 and later * * releases compiling with TEST(NOSEPARATE) * * or equivalent options and running * * programs which abend or generate * * a CEEDUMP. * **************************************************************** * PROBLEM DESCRIPTION: When COBOL fails to initialize DWARF * * information for unknown reasons, * * it might cause a possible memory leak. * **************************************************************** * RECOMMENDATION: Install the provided PTF. * **************************************************************** When a program abends or a CEEDUMP is generated, various data is extracted from DWARF information which is embedded in program objects. When COBOL Runtime fails to initialize the DWARF information for unknown reasons, internal clean-up logic was inadvertently bypassed potentially causing a memory leak. COB0501T/K COB0502T/K COB0601T/K COB0602T/K COB0603T/K COB0604T/K
Problem conclusion
COBOL Runtime logic has been corrected to call the internal clean-up routine 'dwarf_finish' when DWARF initialization fails.
Temporary fix
Comments
APAR Information
APAR number
PH64320
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7E0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-11-26
Closed date
2024-12-05
Last modified date
2025-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZBXITA IGZCEV4 IGZCJNI2 IGZLLIBV IGZRIDT IGZRTMON IGZXAPI IGZXCA31 IGZXCDA IGZXD24 IGZXDMR IGZXJNI2 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7E0","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 January 2025