IBM Support

PH64245: IN AN LP(64) CEEDUMP, THE ODO ARRAYS IN LINKAGE SECTION DO NOT FORMAT CORRECTLY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In an LP(64) CEEDUMP, the ODO arrays in LINKAGE SECTION do not
    format correctly. These areas are missing the formatted contents
    of the individual array occurrences.
    
    
    AMODE31 Local Variables in CEEDUMP  (Correct)
    --------------------------------------------------------
    Local Variables:
     Variables for SUB31:
           22 01 WS-PROGRAM       X(8) DISP          'SUB31   '
           Etc...
           49    05 LS-CACHE-ARRAY   AN-GR  OCCURS 2
           56       10 LS-CACHE-RECORD  AN-GR
           57          15 LS-CACHE-KEY     AN-GR
           58             20 LS-KEY           X(3) DISP
                                SUB(1)
          'A  '
                                SUB(2)
          'B  '
           59          15 LS-CACHE-DATA    AN-GR
           60             20 LS-DATA          S9(3) CMP3
                                SUB(1)
          +001
                                SUB(2)
          *** Invalid data for this data type *** X'0000'
    
    
    AMODE64 Local Variables in CEEDUMP
    --------------------------------------------------------
    From CBLSERV.T01657.S3607.CEEDUMP.MAIN64
    
    Local Variables:
    
    
     Variables for SUB64:
    
    
           22 01 WS-PROGRAM       X(8) DISP         'SUB64   '
    
    
           Etc...
           49    05 LS-CACHE-ARRAY   AN-GR  OCCURS 0
    
    
           56       10 LS-CACHE-RECORD  AN-GR
    
    
           57          15 LS-CACHE-KEY     AN-GR
    
    
           58             20 LS-KEY           X(3) DISP
    
    
           59          15 LS-CACHE-DATA    AN-GR
    
    
           60             20 LS-DATA          S9(3) CMP3
    
    Notice the "OCCURS 0" on LS-CACHE-ARRAY.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 who are        *
    *                 compiling and running programs with the      *
    *                 LP(64) and TEST(DWARF)/NOTEST(DWARF)         *
    *                 compiler options in effect and who need to   *
    *                 view the contents of an ODO table that       *
    *                 resides in the LINKAGE section using either  *
    *                 a CEEDUMP file or the DebugTool debugger.    *
    ****************************************************************
    * PROBLEM DESCRIPTION: An incorrect value of the table's ODO   *
    *                      object is displayed and the contents of *
    *                      the ODO table itself are not displayed  *
    *                      correctly, including the possibility of *
    *                      missing rows.                           *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM-provided PTF                   *
    ****************************************************************
    The DWARF that was generated to describe an ODO table residing
    in the LINKAGE section for a program compiled with the LP(64)
    option in effect was using an incorrect length for the address
    of the table's ODO object.
    

Problem conclusion

  • The compiler was updated to use the correct length of the
    address of the ODO object in the DWARF description of an ODO
    table that resides in the LINKAGE section of a program compiled
    with the LP(64) option in effect.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH64245

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-11-20

  • Closed date

    2024-11-21

  • Last modified date

    2025-01-02

  • APAR is sysrouted FROM one or more of the following:

    PH63224

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI  IGYCOPT  IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI99158

       UP24/12/03 P F412

  • R631 PSY UI99159

       UP24/12/03 P F412

  • R632 PSY UI99160

       UP24/12/03 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date: