A fix is available
APAR status
Closed as program error.
Error description
Incorrect result. The return value of the COMBINED-DATETIME intrinsic function is always calculated as if the INTDATE(ANSI) compiler option is in effect. INTDATE(LILIAN) is not honored.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and * * running programs that are compiled with the * * INTDATE(LILIAN) compiler option in effect * * and the program uses the * * COMBINED-DATETIME intrinsic function. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect result. The return value of * * the COMBINED-DATETIME intrinsic * * function * * is always calculated as if the * * INTDATE(ANSI) * * compiler option were in effect. * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF. * **************************************************************** The COMBINED-DATETIME intrinsic function was not properly accounting for the INTDATE(LILIAN) compiler option.
Problem conclusion
The compiler was updated to ensure that it properly takes into account the setting of the INTDATE(LILIAN) compiler option when processing the COMBINED-DATETIME intrinsic function.
Temporary fix
Comments
APAR Information
APAR number
PH64243
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-11-20
Closed date
2024-11-21
Last modified date
2025-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI99158
UP24/12/03 P F412
R631 PSY UI99159
UP24/12/03 P F412
R632 PSY UI99160
UP24/12/03 P F412
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 January 2025