Error description
The HBRC is executed at start up of IMS by a pre initialization call. HBRC and HBRD in COBOL program take no action to free shared memory. Shared Memory is freed via a termination procedure when IMS is shutdown because the connection remains open until IMS is quit, ODM resource manager termination code gets run. The issue is unlikely to be seen as it only occurs when a customer shuts down a busy server and fails over to a secondary server. In this unique case the termination manager malfunctions and attempts to free the memory of the a server twice.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users with two zRES servers configured to * * an IMS region who bounce zRES servers * * when they are in use, before then * * shutting down the IMS region. * **************************************************************** * PROBLEM DESCRIPTION: The HBRC is done at start up of IMS by * * a pre initialization call. * * HBRC and HBRD in COBOL program take no * * action to free shared * * memory. * * Shared Memory is freed via a * * termination procedure when IMS is * * shutdown * **************************************************************** * RECOMMENDATION: The issue is unlikely to be seen as it * * only occurs when a * * customer shuts down a busy server * * and fails over to a * * secondary server. * * In this unique case the termination * * manager * * malfunctions and attempts to free the * * memory of the a server * * twice. * * * * Only apply this fix if you are seeing the * * IMS Abend and wish to correct it. * **************************************************************** Only apply this fix if you are seeing the IEA705I Error during freemain SYS code = 378-18 IMS Abend and wish to correct it.
Problem conclusion
Temporary fix
Comments
PROBLEM CONCLUSION: Install these PTFs to keep the zRES running in Console or HTDS mode supported.
APAR Information
APAR number
PH64145
Reported component name
WS BUS RULES Z/
Reported component ID
5655Y3100
Reported release
A50
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-11-14
Closed date
2025-06-26
Last modified date
2025-06-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"A50"}]
Document Information
Modified date:
26 June 2025