IBM Support

PH64145: IEA705I Error during freemain SYS code = 378-18 when restarting zRes before then stopping IMS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • The HBRC is executed at start up of IMS by a pre initialization
    call.
    HBRC and HBRD in COBOL program take no action to free shared
    memory.
    Shared Memory is freed via a termination procedure when IMS is
    shutdown because the connection remains open until IMS
    is quit, ODM resource manager termination code gets run.
    
    
    The issue is unlikely to be seen as it only occurs when a
    customer shuts down a busy server and fails over to a
    secondary server. In this unique case the termination manager
    malfunctions and attempts to free the memory of the a server
    twice.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users with two zRES servers configured to    *
    *                 an IMS region who bounce zRES servers        *
    *                 when they are in use, before then            *
    *                 shutting down the IMS region.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: The HBRC is done at start up of IMS by  *
    *                       a pre initialization call.             *
    *                      HBRC and HBRD in COBOL program take no  *
    *                       action to free shared                  *
    *                      memory.                                 *
    *                      Shared Memory is freed via a            *
    *                      termination procedure when IMS is       *
    *                      shutdown                                *
    ****************************************************************
    * RECOMMENDATION: The issue is unlikely to be seen as it       *
    *                  only occurs when a                          *
    *                 customer shuts down a busy server            *
    *                 and fails over to a                          *
    *                 secondary server.                            *
    *                 In this unique case the termination          *
    *                 manager                                      *
    *                 malfunctions and attempts to free the        *
    *                  memory of the a server                      *
    *                 twice.                                       *
    *                                                              *
    *                 Only apply this fix if you are seeing the    *
    *                 IMS Abend and wish to correct it.            *
    ****************************************************************
    Only apply this fix if you are seeing the
    IEA705I Error during freemain SYS code = 378-18
    IMS Abend and wish to correct it.
    

Problem conclusion

Temporary fix

Comments

  • PROBLEM CONCLUSION:
    Install these PTFs to keep the zRES running in Console or
    HTDS mode supported.
    

APAR Information

  • APAR number

    PH64145

  • Reported component name

    WS BUS RULES Z/

  • Reported component ID

    5655Y3100

  • Reported release

    A50

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-11-14

  • Closed date

    2025-06-26

  • Last modified date

    2025-06-26

  • APAR is sysrouted FROM one or more of the following:

    PH54943

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"A50"}]

Document Information

Modified date:
26 June 2025