APAR status
Closed as program error.
Error description
Running Headless Code Coverage on a program that was not compiled with the TEST debug parameter will result in an empty output directory and non existent code coverage report. The output directory is removed/cleaned because an error was encountered collecting code coverage data. This condition is encountered when (1) -singleconnection is used, AND (2) the incoming code coverage job, has no code coverage result (in this case, due to no debug data with NOTEST compile option). In the absence of the TEST debug parameter, there will be no data for the debug engine to find. Due to the removal of the output directory and log, the user is unable to view or act on any errors that may have been reported.
Local fix
Compile the target program with the TEST debug parameter to avoid this error condition.
Problem summary
**************************************************************** * USERS AFFECTED: * * All headless Code Coverage users * **************************************************************** * PROBLEM DESCRIPTION: * * Output directory gets deleted when there is an error during * * headless code coverage collection and -singleconnect option * * is used. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
This problem is fixed in versions 16.0.7 and 17.0.1 for the following products: - IBM Debug for z/OS - IBM Developer for z/OS - IBM Developer for z/OS Enterprise Edition
Temporary fix
Comments
APAR Information
APAR number
PH64024
Reported component name
DEV FOR Z/OS
Reported component ID
5724T0700
Reported release
G00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-11-06
Closed date
2025-05-08
Last modified date
2025-05-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G00"}]
Document Information
Modified date:
09 May 2025