A fix is available
APAR status
Closed as new function.
Error description
-
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 and later * * releases running programs * * compiled with new LSACHECK option. * **************************************************************** * PROBLEM DESCRIPTION: NEW FUNCTION. * **************************************************************** * RECOMMENDATION: Install the provided PTF. * **************************************************************** None. COB0603T/K COB0604T/K
Problem conclusion
Temporary fix
Comments
NEW FUNCTION. When a COBOL program is compiled with a new LSACHECK option, erroneous access to LINKAGE SECTION at program runtime consequently causes the program to be terminated with an 0C4 abend. If the COBOL runtime can diagnose the erroneous access, new COBOL Runtime messages (IGZ0401W and IGZ0402W) are issued prior to the 0C4 abend to assist in locating the erroneous access. For the IGZ0401W and IGZ0402W, refer to https://www.ibm.com/support/pages/node/563753 For the LSACHECK option, refer to COBOL compiler APAR PH63907.
APAR Information
APAR number
PH63898
Reported component name
LE COBOL LIB
Reported component ID
568819802
Reported release
7E0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2024-10-28
Closed date
2024-11-22
Last modified date
2025-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI99165 UI99166 UI99171 UI99172
Modules/Macros
IGZBALCT IGZCEV4 IGZCJNI2 IGZCMGEN IGZCMGJA IGZCMGUE IGZEDCCT IGZIBMCT IGZIGZCT IGZLLIBV IGZXAPI IGZXCA31 IGZXCDA IGZXD24 IGZXDMR IGZXJNI2 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7D0 PSY UI99165
UP24/12/03 P F412
R7DJ PSY UI99166
UP24/12/03 P F412
R7E0 PSY UI99171
UP24/12/03 P F412
R7EJ PSY UI99172
UP24/12/03 P F412
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7E0","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 January 2025