A fix is available
APAR status
Closed as program error.
Error description
For a data set spanning over multiple volumes, dls prints information about the data set for one volume and prints and information message stating additional details cannot be provided for the other volume. Eg: bash-4.3$ dls -s $dsn USER.PRIVATE.TESTDS PS FB 15 000000 0 4249800 BGYSC2006I Unable to obtain dataset information for dataset USER.PRIVATE.TESTDS on volume 222222. 1.3.3.2
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Z Open Automation Utilities * * (ZOAU) version 1.3.x * **************************************************************** * PROBLEM DESCRIPTION: When a user invokes dls using the -l * * option to display the details of a * * multi-volume dataset, only one line of * * output is properly printed. The * * remaining lines display the error * * message BGYSC2006I. * * * * This PTF resolves the issue. A line of * * output is now properly printed for each * * utilized volume. * **************************************************************** * RECOMMENDATION: APPLY APAR/PTF. Follow instructions in PTF * * HOLDs. * **************************************************************** This APAR (PH63491) supplies ZOAU v1.3.3.2 To learn more about installing ZOAU, see: https://ibm.biz/zoau-install If you use the ZOAU Python language bindings, you may need to take further actions to upgrade them on your system. Follow the instructions for "Install ZOAU Python APIs" in the ZOAU documentation.
Problem conclusion
-----
Temporary fix
Comments
APAR Information
APAR number
PH63491
Reported component name
Z OPEN AUTO UTL
Reported component ID
5724T0753
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-10-01
Closed date
2024-10-22
Last modified date
2024-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI98845
Modules/Macros
BGY310W3 BGY311W3 BGY312W3 BGY39W3 BGYBIN3 BGYCONF3 BGYDOCS3 BGYINCL3 BGYLIB3 BGYLICS3 BGYPTGZ3 BGYRDME3 BGYSAMP3 BGYSTUB3 BGYZOAU3
Fix information
Fixed component name
Z OPEN AUTO UTL
Fixed component ID
5724T0753
Applicable component levels
R130 PSY UI98845
UP24/10/24 P F410
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSKFYE","label":"IBM Z Open Automation Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
03 November 2024