A fix is available
APAR status
Closed as program error.
Error description
An unload can terminate in abend (of unpredictable code among which ABENDS0C4) when the following conditions are fulfilled : - the data is unloaded from an image copy (COPYDDN option) - the input image copy is not a FlashCopy and does not need to be sorted (non-inline image copy and INLINE option not specified) - zIIP processors are used to process the unload (i.e. messages such as INZU313I THE process PROCESS USES ZIIP PROCESSORS are issued) - the method to read the image copy is BSAM, method reported by the follwing message INZU666I BSAM METHOD IS USED TO ACCESS TO THE SEQUENTIAL INPUT IMAGE COPIES AS REQUESTED BY SEQ_IO_METHOD OPTION IF ANY OR VUM039/IOMETHOD PARMLIB PARAMETER OTHERWISE
Local fix
request the QSAM method be used to read the image copy by specifying IO_SEQ_METHOD INPUT(QSAM) in the GLOBAL options block.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 High Performance Unload for * * z/OS * **************************************************************** * PROBLEM DESCRIPTION: An unload can terminate in abend (of * * unpredictable code among which * * ABENDS0C4) when the following * * conditions are fulfilled : * * - the data is unloaded from an image * * copy (COPYDDN option) * * - the input image copy is not a * * FlashCopy and does not need to be * * sorted (non-inline image copy and * * INLINE option not specified) * * - zIIP processors are used to process * * the unload (i.e. messages such as * * INZU313I THE process PROCESS USES * * ZIIP PROCESSORS are issued) * * - the method to read the image copy is * * BSAM, method reported by the * * following message : * * INZU666I BSAM METHOD IS USED TO * * ACCESS TO THE SEQUENTIAL INPUT IMAGE * * COPIES AS REQUESTED BY SEQ_IO_METHOD * * OPTION IF ANY OR VUM039/IOMETHOD * * PARMLIB PARAMETER OTHERWISE * * * * Local fix : request the QSAM method be * * used to read the image copy by * * specifying IO_SEQ_METHOD INPUT(QSAM) * * in the GLOBAL options block. * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** unpredictable abend when unloading from an image copy if the image copy is read in BSAM mode
Problem conclusion
Code has been changed to fix this problem
Temporary fix
Comments
APAR Information
APAR number
PH63450
Reported component name
DB2 HI PERF UNL
Reported component ID
5697F4400
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-09-27
Closed date
2024-10-07
Last modified date
2024-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
INZTVAR INZUTILK
Fix information
Fixed component name
DB2 HI PERF UNL
Fixed component ID
5697F4400
Applicable component levels
R520 PSY UI98645
UP24/10/10 P F410
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.