A fix is available
APAR status
Closed as program error.
Error description
An INSPECT {source} TALLYING {count} FOR LEADING SPACES (or FOR ALL SPACES) statement gives an incorrect count, and the generated code is found to be using a constant value instead of the {source}.
Local fix
Compile at OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling * * programs at OPT(1|2) that have two data * * items that share the same storage where a * * value is stored in one of the items, the * * REVERSE function is used on the other item, * * and then the first item is used in another * * statement. * **************************************************************** * PROBLEM DESCRIPTION: The result of the statement using the * * first data item following the REVERSE * * uses the value stored in the first * * item before the REVERSE, not the * * reversed value. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler didn't account for the REVERSE modifying the first data item indirectly (as modifying the value for the second item also modifies the value for the first).
Problem conclusion
The compiler was fixed to account for REVERSE modifying the first data item.
Temporary fix
Comments
APAR Information
APAR number
PH63328
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-09-19
Closed date
2024-11-21
Last modified date
2025-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PH63799 UI99158 UI99159 UI99160
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI99158
UP24/12/03 P F412
R631 PSY UI99159
UP24/12/03 P F412
R632 PSY UI99160
UP24/12/03 P F412
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 January 2025