A fix is available
APAR status
Closed as program error.
Error description
Compiler abort when STGOPT in effect with unreferenced Java-shareable data items
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 building * * non-OO COBOL/Java interoperable applications * * with the STGOPT compiler option in effect, * * and where a COBOL program in the application * * contains no explicit references to at least * * one data item under the scope of a * * JAVA-SHAREABLE directive. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abort with message: * * * * CURRENT PHASE: IGYCPGEN * * CURRENT LINE NUMBER: 000000 * * REGISTERS 0 - 15: * * 2B3AA456 00000000 00073F9C 00000003 * * 00026DD0 00000000 00000000 00073F49 * * 00000000 00000000 0001DA14 26835BB8 * * 2B3AA324 2B3AA068 A6835906 A6835DDA * * PP 5655-EC6 IBM Enterprise COBOL for * * z/OS 6.4.0 P240202 COBPROD * * Date 06 * * LineID Message code Message text * * IGYPG5125-U The compilation was * * terminated due to a compiler error * * in phase id: "IGYCPGEN". * * IGYPG5201-U Internal compiler error * * code "PTEXT-07" occurred. * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF. * **************************************************************** The issue occurs when STGOPT optimization incorrectly removed the storage of an unreferenced JAVA-SHAREABLE data item.
Problem conclusion
The compiler has been updated to ensure that unreferenced data items under the scope of a JAVA-SHAREABLE directive are not removed when the STGOPT compiler option is in effect.
Temporary fix
Comments
APAR Information
APAR number
PH63277
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-09-17
Closed date
2024-10-22
Last modified date
2024-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI98832
UP24/10/31 P F410
R641 PSY UI98833
UP24/10/31 P F410
R642 PSY UI98834
UP24/10/31 P F410
R64H PSY UI98835
UP24/10/31 P F410
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
03 November 2024