A fix is available
APAR status
Closed as program error.
Error description
When changing passwords failed and the maximum number of attempts was exceeded, an ABEND0C4 may occur at RSMEXT subroutine in CEXSVC01 (Client services exit).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V3.1 * **************************************************************** * PROBLEM DESCRIPTION: S0C4 in CEXSVC01 when changing * * passwords failed and exceeding their * * violation limit causing revocation * **************************************************************** When changing passwords failed and the maximum number of attempts was exceeded, there might occur S0C4 abend at RSMEXT subroutine in CEXSVC01 (Client services exit).
Problem conclusion
Improve validation code in CEXSVC01.
Temporary fix
Comments
APAR Information
APAR number
PH63236
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-09-13
Closed date
2024-09-24
Last modified date
2024-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI98523
Modules/Macros
CEXAUTH0 CEXCONS CEXCONSC CEXEXRTR CEXSVC01 CEXVUSER
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R310 PSY UI98523
UP24/09/27 P F409
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: