A fix is available
APAR status
Closed as program error.
Error description
To enhance the UMS, during the RESUME Apply Changes process, the modified object's name and type should be retrieved from the failed Apply WLS map entry rather than the API request. This change will prevent the null pointer exception and ensure the API returns a 200 status code.
Local fix
NA
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Db2 DevOps Experience for z/OS * **************************************************************** * PROBLEM DESCRIPTION: The RESUME Apply Object Changes API * * currently throws a null pointer * * exception and returns a 500 status * * code. * **************************************************************** During the RESUME Apply Changes process, the modified object's name and type should be retrieved from the failed Apply WLS map entry rather than the API request. This change will prevent the null pointer exception and ensure the API returns a 200 status code.
Problem conclusion
Apply the PTF provided by this APAR
Temporary fix
Comments
APAR Information
APAR number
PH63022
Reported component name
UNIFIED MGMT SV
Reported component ID
5698UM100
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-08-30
Closed date
2024-11-12
Last modified date
2025-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IZP2IFIP IZPD2A IZPD2R IZPD2T IZPD2VA IZPD2VR IZPD2VT IZPD3T IZPD3VT IZPDAJP IZPDATPP IZPDISCP IZPHLVP IZPJOBSP IZPMNFST IZPSERVE IZPUI IZPUSCP
Fix information
Fixed component name
UNIFIED MGMT SV
Fixed component ID
5698UM100
Applicable component levels
R120 PSY UI99021
UP24/11/20 P F411
Fix is available