IBM Support

PH62877: REORG AVOIDANCE: COMMUNICATION WITH QUERY MONITOR (CQM) CAN FAILWHEN A LARGE VOLUME OF DB2 OBJECTS IS PASSED TO CQM

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When large volumes of Db2 objects are passed to Db2 Query
    Monitor (CQM) via a job profile containing a QUERY MONITOR
    REORG_OVERRIDE exception specified, the communication with CQM
    can become corrupted.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: This PTF corrects the following issue:  *
    *                                                              *
    *                      When large volumes of Db2 objects are   *
    *                      passed to Db2 Query Monitor (CQM) via a *
    *                      job profile containing a QUERY MONITOR  *
    *                      REORG_OVERRIDE exception specified, the *
    *                      communication with CQM can become       *
    *                      corrupted.                              *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF                                *
    ****************************************************************
    .
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH62877

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    430

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-08-21

  • Closed date

    2024-10-17

  • Last modified date

    2024-11-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI98801

Modules/Macros

  • HAAXNR02
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R430 PSY UI98801

       UP24/10/19 P F410

Fix is available