IBM Support

PH62509: Fields with "Code page conversion" disabled and "Omit fields with uniform byte values" set are not omitted.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • Code page conversion is disabled for a field in the API
    Toolkit service.properties "Advanced Options..." and the "Omit
    fields with uniform byte values" check box is selected with
    value 0x'00'.
    If low values are passed in that field, the field is not
    omitted.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/OS Connect V3.0 OpenAPI 2 API *
    *                 providers.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Fields with "Code page conversion"      *
    *                      disabled are not omitted.               *
    ****************************************************************
    Fields specified with "Code page conversion" disabled were
    treated as UTF-8 rather than String data. Only fields defined as
    Strings were omitted. This caused the fields specified with code
    page conversion disabled to incorrectly appear in the response
    data.
    

Problem conclusion

Temporary fix

Comments

  • z/OS Connect has been changed to honor the "Omit fields with
    uniform byte values" for fields with code page conversion
    disabled.
    
    The fix for this APAR is expected to be delivered by the PTF for
    z/OS Connect EE V3.0.91.0 (PH65316).
    

APAR Information

  • APAR number

    PH62509

  • Reported component name

    Z/OS CONNECT EE

  • Reported component ID

    5655CE300

  • Reported release

    000

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-07-29

  • Closed date

    2025-03-07

  • Last modified date

    2025-03-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    Z/OS CONNECT EE

  • Fixed component ID

    5655CE300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVVFY","label":"z\/OS Connect Enterprise Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"000"}]

Document Information

Modified date:
07 March 2025