APAR status
Closed as unreproducible in next release.
Error description
Code page conversion is disabled for a field in the API Toolkit service.properties "Advanced Options..." and the "Omit fields with uniform byte values" check box is selected with value 0x'00'. If low values are passed in that field, the field is not omitted.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of z/OS Connect V3.0 OpenAPI 2 API * * providers. * **************************************************************** * PROBLEM DESCRIPTION: Fields with "Code page conversion" * * disabled are not omitted. * **************************************************************** Fields specified with "Code page conversion" disabled were treated as UTF-8 rather than String data. Only fields defined as Strings were omitted. This caused the fields specified with code page conversion disabled to incorrectly appear in the response data.
Problem conclusion
Temporary fix
Comments
z/OS Connect has been changed to honor the "Omit fields with uniform byte values" for fields with code page conversion disabled. The fix for this APAR is expected to be delivered by the PTF for z/OS Connect EE V3.0.91.0 (PH65316).
APAR Information
APAR number
PH62509
Reported component name
Z/OS CONNECT EE
Reported component ID
5655CE300
Reported release
000
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-07-29
Closed date
2025-03-07
Last modified date
2025-03-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
Z/OS CONNECT EE
Fixed component ID
5655CE300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVVFY","label":"z\/OS Connect Enterprise Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"000"}]
Document Information
Modified date:
07 March 2025