A fix is available
APAR status
Closed as program error.
Error description
This APAR will address the following issues: - When attempting to extract CICS RACF transaction settings, if a non-existent class is specified for XTRAN then the following message is produced: ERROR: No users found in the specified classes This message is miss-leading as it indicates no users have been found, however the problem is that the class specified is incorrect. - ESM file contains an incorrect resource name for XRES. A logic error means that only the last qualifier is being output as the resource name. eg: prefix.restype.resname is output as resname - Some metadata is not obsfucated when HIDE=YES is used - Security Metadata fails to load with a definition that has an invalid access level.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: This APAR addresses a number of minor * * security metadata issues found after * * the GA of CICS TS 6.2. * **************************************************************** 1) When attempting to extract CICS RACF transaction settings, if a non-existent class is specified for XTRAN then the following message is produced: ERROR: No users found in the specified classes This message is miss-leading as it indicates no users have been found, however the problem is that the class specified is incorrect. 2) A logic error results in an ESM file containing an incorrect resource name for XRES. Only the last qualifier is being output as the resource name. eg: prefix.restype.resname is output as resname 3) Some metadata is not obsfucated when HIDE=YES is used 4) Security Metadata fails to load with a definition that has an invalid access level.
Problem conclusion
The above issues have been addressed and corrected.
Temporary fix
Comments
APAR Information
APAR number
PH62097
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-06-28
Closed date
2024-07-26
Last modified date
2024-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI97802
Modules/Macros
DFH$XSU
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R500 PSY UI97802
UP24/07/27 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.2","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: