IBM Support

PH62064: INCORRECT PROCESSING KEY MAY CAUSE AN S0C4 ABEND IN AN MPP REGION 24/07/18 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • It is possible for a MPP region to ABEND with a S0C4 when
    validating storage to be used as the work area for the compiled
    filter program. This ABEND is due to the potential for the
    address used being inaccessible in execution key 7. This code
    change switches to execution key 0 when performing the storage
    area validation.
    APARs PH60078 and PH61129 are superseded by this APAR.
    

Local fix

  • NA
    

Problem summary

  • This APAR corrects an issued created by PH60078 which has
    been flagged P.E.
    It is possible for a MPP region to ABEND with
    a S0C4 when validating storage to be used as the
    work area for the compiled filter program.
    This ABEND is due to the potential for the address
    used being inaccessible in execution key 7.
    This code change switches to execution key 0
    when performing the storage area validation.
    
    APARs PH60078 and PH61129 are superseded by this APAR.
    

Problem conclusion

  • PH62064- Incorrect processing key may cause an S0C4
    abend in an MPP region
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH62064

  • Reported component name

    SEC GUAR STAP I

  • Reported component ID

    5655STM00

  • Reported release

    B30

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-06-26

  • Closed date

    2024-07-15

  • Last modified date

    2024-08-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI97648

Modules/Macros

  • AUICPY4E AUICPY4F AUIDLA0E AUIDLA0F
    

Fix information

  • Fixed component name

    SEC GUAR STAP I

  • Fixed component ID

    5655STM00