A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4-11 in CQMMZIIP+X'388E' and a subsequent ABEND0C1 in CQCMZIIP due to the shutdown process eliminating the underlying storage for both of those modules.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Db2 Query Monitor * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** ABEND0C4-11 in CQMMZIIP+X'388E' and a subsequent ABEND0C1 in CQCMZIIP due to the shutdown process eliminating the underlying storage for both of those modules.
Problem conclusion
The recovery routine and the routine itself were moved to persistent memory to avoid the issue
Temporary fix
Comments
APAR Information
APAR number
PH61872
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
340
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-06-14
Closed date
2024-07-24
Last modified date
2024-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQM#BCMX CQM#INIX CQM#PARM CQMMEXCX CQMMINIX CQMMSCCX CQMMSCPX CQMMSCRX CQMMSCSX CQMMSDCX CQMMSDPX CQMMSDRX CQMMSDSX CQMMZIIP CQMZEMTR CQMZEXCP CQMZEXCS
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R340 PSY UI97776
UP24/08/14 P F408 ¢