Error description
The Activity Log configuration service does provide an option to apply the configurable service to one or all of the integration servers on the integration node. The default is 'all' and in this case, it is possible that one or more of the integration servers may abend with the following abend stack: ImbConfigurationException::throwThis() ImbFile::write(const char*,int) ImbRotatableLogFile::write(const void*,int) ImbActivityLogFile::write(const ImbActivityLogEntry&) ImbActivityLogManager::writeActivityLogEntry(ImbActivityLogE ImbActivityLogManager::writeActivityLogEntryStatic(ImbActivi
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus v10.1 using ActivityLog configurable service Platforms affected: ZOS **************************************************************** PROBLEM DESCRIPTION: The Activity Log configurableservice provides an option to apply the configurable service to one or all of the integration servers on the integration node. The default is 'all' and in such case, it is possible that one or more of the integration servers may abend when they all try to write to the same activity log file.
Problem conclusion
The product has been updated to introduce a new option, "executionGroupSpecificLogs", in the activity log configurable service. This option can be set to true or false, allowing users to specify whether to generate a separate activity log file for each Integration Server. If you select this option, then the 'activitylog file name' will be used to create a specific activitylogfile_EGname file for each of the integration servers. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.1 10.1.0.7 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
PH61557
Reported component name
INT BUS FOR Z/O
Reported component ID
5655AB110
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-05-29
Closed date
2025-09-25
Last modified date
2025-09-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INT BUS FOR Z/O
Fixed component ID
5655AB110
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSNQH8","label":"IBM Integration Bus for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]
Document Information
Modified date:
25 September 2025