A fix is available
APAR status
Closed as program error.
Error description
When shutting down the SCI address space and then shutting down the QCF Server, an ABENDS0C4 may occur in the Notify Exit module called by CSLSSR20 if multiple QCF servers that belong to the same PLEX are shut down at the same time. At this time, one of the following messages is shown: CSL3110E MEMBER qcf_sever_name EXIT SRB ABEND S0C4 PSW=psw RSN=00000011 CSLSSR20=module_address EXIT=exit_address IN EXIT or CSL3110E MEMBER qcf_sever_name EXIT SRB ABEND S0C4 PSW=psw RSN=00000010 CSLSSR20=module_address EXIT=exit_address IN EXIT or CSL3110E MEMBER qcf_sever_name EXIT SRB ABEND S0C4 PSW=psw RSN=00000004 CSLSSR20=module_address EXIT=exit_address IN EXIT RSN=00000011 is abended at IQCZPLM0 + x'0424' RSN=00000010 is abended at IQCZPLM0 + x'041C' RSN=00000004 is abended at IQCZXNF0 + x'030A' S0C4
Local fix
Either of the following two steps will alleviate the abend: - Shut down the QCF Server and then shut down the SCI address space. - When shutting down multiple QCF Servers belonging to the same PLEX, shut them down in order with an interval of about 10 seconds.
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Queue Control Facility for z/OS * * Version 3 Release 2 (FMID=H0GN320) users. * **************************************************************** * PROBLEM DESCRIPTION: When shutting down the SCI address * * space and then shutting down the QCF * * Server, an ABENDS0C4 may occur in the * * Notify Exit module called by CSLSSR20 * * if multiple QCF servers that belong to * * the same PLEX are shut down at the same * * time. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** If the SCI address space has already been stopped, when the Notify Exit receives a notification from the QCF Server on another node during the QCF server shutdown process, it may reference an area that has already been freed. This results in an abend with S0C4. At this time, one of the following messages is shown: CSL3110E MEMBER qcf_sever_name EXIT SRB ABEND S0C4 PSW=psw RSN=00000011 CSLSSR20=module_address EXIT=exit_address IN EXIT or CSL3110E MEMBER qcf_sever_name EXIT SRB ABEND S0C4 PSW=psw RSN=00000010 CSLSSR20=module_address EXIT=exit_address IN EXIT or CSL3110E MEMBER qcf_sever_name EXIT SRB ABEND S0C4 PSW=psw RSN=00000004 CSLSSR20=module_address EXIT=exit_address IN EXIT RSN=00000011 is abended at IQCZPLM0 + x'0424' RSN=00000010 is abended at IQCZPLM0 + x'041C' RSN=00000004 is abended at IQCZXNF0 + x'030A'
Problem conclusion
QCF has been changed to ignore notifications received by the Notify Exit during the QCF Server shutdown process.
Temporary fix
Comments
APAR Information
APAR number
PH61498
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-05-24
Closed date
2024-09-19
Last modified date
2024-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI98480
Modules/Macros
IQCZXNF0
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI98480
UP24/09/21 P F409
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.