IBM Support

PH61440: Saving compare summary report results in SQL -803 Error

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When "Save compare results" is set to YES on the GOC5 panel, the
    resulting compare errors out with SQL -803 due to a duplicate
    row being generated for table ADBCMPREPOBJLINES.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Administration Tool for z/OS    *
    *                 who save Object Compare Results              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Saving compare results ends with        *
    *                      SQLCODE -803 due to a duplicate row     *
    *                      sequence number.                        *
    ****************************************************************
    When saving comparison results for multiple tables with a large
    number of partitions, an SQLCODE -803 is issued. This error is
    due to a duplicate sequence number being issued for the row that
    is inserted into the Comparison Results CM table
    (ADBCMREPOBJLINES).
    
    Search keywords: SQLCODE803N
    

Problem conclusion

  • The problem has been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH61440

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-05-21

  • Closed date

    2024-11-25

  • Last modified date

    2024-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI99193

Modules/Macros

  • ADB2CME  ADB2CMT
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RD10 PSY UI99193

       UP24/12/03 P F411

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.