Error description

  • There is the potential for a S0C4 ABEND in module AUILOG00 due
    to an invalid CCKEY or Segment data address being recorded.
    The S0C4 can occur if the address obtained, causes a protection
    exception, which may or may not be the case.
    If the S0C4 does occur, the ESTAE recovery process in AUILOG00
    will disable auditing until the IMS is restarted.
    The invalid CCKEY and Segment data address can be produced when:
    1) The user has requested that DLI calls that receive a GE
    Status code (Segment unavailable) be audited and sent to the
    appliance.
    2) The DLI call that hits or exceeds the message AUII050I (DLI
    call counts) frequency limit is slated to not be audited.
    This APAR can be installed without restarting the IMS online
    sub-system by following the IMS STAP Dynamic IMS Maintenance
    Enablement (DIME) processes.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * PROBLEM DESCRIPTION: S0C4 ABEND in AUILOG00 possible due to  *
    *                      invalid CCKEY or Segment data addresses *
    ****************************************************************
    S0C4 ABEND in AUILOG00 possible due to invalid CCKEY or
    Segment data addresses
    

Problem conclusion

  • There is the potential for a S0C4 ABEND in module AUILOG00
    due to an invalid CCKEY or Segment data address being recorded.
    The S0C4 can occur if the address obtained,
    causes a protection exception, which may or may not
    be the case.
    If the S0C4 does occur, the ESTAE recovery process in AUILOG00
    will disable auditing until the IMS is restarted.
    The invalid CCKEY and Segment data address can be produced when:
    1) The user has requested that DLI calls that receive
    a GE Status code (Segment unavailable) be audited and
     to the appliance.
    2) The DLI call that hits or exceeds the message AUII050I
    (DLI call counts) frequency limit is slated to not be audited.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH61129

  • Reported component name

    SEC GUAR STAP I

  • Reported component ID

    5655STM00

  • Reported release

    B30

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-04-29

  • Closed date

    2024-05-20

  • Last modified date

    2024-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI96973

Modules/Macros

  • AUICPY4E AUICPY4F AUIDLA0E AUIDLA0F
    

Fix information

  • Fixed component name

    SEC GUAR STAP I

  • Fixed component ID

    5655STM00

Applicable component levels

  • RB30 PSY UI96973

       UP24/05/24 P F405

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B30","Line of Business":{"code":"LOB24","label":"Security Software"}}]

Document Information

Modified date:
19 July 2024