Error description

  • Currently the tracker sends event records to the controller some
    of which have a flag to indicate that they are related to
    dataset trigger processing.  The controller decides if any
    dynamic special resource ( SR ) needs to be added.  So it should
    be possible to add some tracing on the controller side based
    on this "ETT" flag to help determine what specific event record
    caused an SR action to be taken.  This could in turn help with
    the clean up of the EQQDSLST entries.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All WAz experienced users who need           *
    *                 a specific optimization of the data set      *
    *                 triggering in their environments.            *
    *                                                              *
    *                 FUNCTION: Data set triggering                *
    ****************************************************************
    * PROBLEM DESCRIPTION: This apar allows by diagnostic option   *
    *                      the acknowledgement of which data set   *
    *                      triggering definitions are producing    *
    *                      special resource events and if these    *
    *                      events find a match in the ETT          *
    *                      criteria, causing a dynamic special     *
    *                      resource ADD.                           *
    *                      This acknowledgement comes both from    *
    *                      the Tracker and from the Controller.    *
    ****************************************************************
    This apar allows by diagnostic option the acknowledgement of
    which data set  triggering definitions are producing
    special resource events and if these events find a match in the
    ETT criteria, causing a dynamic special resource ADD.
    This acknowledgement comes both from
    the Tracker and from the Controller.
    

Problem conclusion

Temporary fix

Comments

  • The tool implemented by this apar is for experienced
    customers. It can be activated by means of
    a DIAGNOSE statement setting, that can
    also be dynamically activated and
    deactivated.
    The functionality and use of the tool is detailed in the
    tech note, document number 7180062. The title is "A tool to
    optimize data set triggering".
    

APAR Information

  • APAR number

    PH61114

  • Reported component name

    TIV WRKLD SCHD

  • Reported component ID

    5697WSZ01

  • Reported release

    950

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2024-04-26

  • Closed date

    2024-12-31

  • Last modified date

    2025-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI99539 UI99540 UI99541 UI99542

Modules/Macros

  • EQQEMAPP EQQEMEVQ EQQEMJPS EQQEMSRD EQQEMSRS EQQEWEVH EQQZCMDT
    EQQZEVJN EQQZEVSX
    

Fix information

  • Fixed component name

    TIV WRKLD SCHD

  • Fixed component ID

    5697WSZ01

Applicable component levels

  • R950 PSY UI99539

       UP25/02/12 P F502  

  • R952 PSY UI99540

       UP25/02/12 P F502  

  • RA10 PSY UI99541

       UP25/02/12 P F502  

  • RA12 PSY UI99542

       UP25/02/12 P F502  