A fix is available
APAR status
Closed as program error.
Error description
The internal utility `relgen` used to resolve a GDS relative name is miscalculating the generation level when a negative generation level is provided and the GDG has skipped generations. This is impacting dcp, dgrep, mls and mrm. The other utilities do not use relgen. For example: 1. The GDG has some gaps between generations, example: GDG.G0001V00 GDG.G0002V00 GDG.G0005V00 GDG.G0006V00 2. A negative generation level that should skip generations is provided. relgen GDG(-2) Expected result: This should resolve to the generation level GDG.G0002V00. Actual result: BGYSC6009E The computed generation is not active in the GDG
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Z Open Automation Utilities * * (ZOAU) version 1.3.0.x * **************************************************************** * PROBLEM DESCRIPTION: A generation data set negative relative * * name resolution provides an incorrect * * result when the generation data group * * contains gaps between generations. * * * * For example, in the case where a GDG * * contains two active generations, * * GDG.G0001V00 and GDG.G0003V00, the * * resolution of the name GDG(-1) * * incorrectly throws the error * * "BGYSC6009E". * * * * The computed generation 2 is not active * * in the GDG", when it should actually * * resolve to the name GDG.G0001V00. * * * * This PTF fixes this issue, which * * affects dcp, dgrep, mls, mmv, and mrm. * **************************************************************** * RECOMMENDATION: APPLY APAR/PTF. Follow instructions in PTF * * HOLDs. * **************************************************************** This is a maintenance release with a single bug fix. It is a full replacement for all prior versions of ZOAU 1.3.x.
Problem conclusion
*****
Temporary fix
Comments
APAR Information
APAR number
PH60717
Reported component name
Z OPEN AUTO UTL
Reported component ID
5724T0753
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-04-04
Closed date
2024-04-10
Last modified date
2024-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI96474
Modules/Macros
BGY310W3 BGY311W3 BGY312W3 BGY39W3 BGYBIN3 BGYCONF3 BGYDOCS3 BGYINCL3 BGYLIB3 BGYLICS3 BGYPTGZ3 BGYRDME3 BGYSAMP3 BGYSTUB3 BGYZOAU3
Fix information
Fixed component name
Z OPEN AUTO UTL
Fixed component ID
5724T0753
Applicable component levels
R130 PSY UI96474
UP24/04/12 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSKFYE","label":"IBM Z Open Automation Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 May 2024