Error description
Turning ON only snip 1, 2 & 7, the pack is not doing claim level rejection, it is producing only invalid file. But with SNIP 1, 2 , either 3 or 4 and 7, it is doing the claim level rejection and producing both valid and invalid files. An 837 file having only one ST-SE and 3 claims, with a T7 rule, on 2400 CN1 segment. Only 1 claim should fail and the rest should go into valid file. This discrepancy for all 3 file types (I, P and D).
Local fix
ITXCQ - ITX00062374 LV / LV Circumvention: None
Problem summary
IBM Transformation Extender Pack for Healthcare HIPAA Problem Description: Turning ON only snip 1, 2 & 7, only produces an invalid file with no claim level rejection. Platforms Affected: ALL
Problem conclusion
Problem Conclusion: hipaa_data_compliance and compliance_check maps updated to proceed with claim level rejection for types 5,6, or 7 with only type 2 enabled. Type 4 enabled is not required. Applies to: Healthcare Pack HIPAA 10.2.1, 10.2.2. Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/ transformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH60400
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-03-18
Closed date
2024-04-02
Last modified date
2024-09-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]
Document Information
Modified date:
30 September 2024