IBM Support

PH59960: NULL BINARY TYPES ARE NOT PROPERLY HANDLED USING THE ODBC ADAPTER

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Null binary types are not properly handled using the ODBC
    adapter.
    
    The following message can be seen in the Database trace log
    file.
    
    Warning: ODBC Column truncated from database length -1
    

Local fix

  • ITXCQ - ITX00062344
    GK / GK
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender users using the ODBC adapter and who
    
    are retrieving binary types.
    
    Problem Description:
    Null binary types are not properly handled with the ODBC
    adapter.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Null binary types are detected and properly processed.
    
    Applies to:
    10.0.1.3, 10.1.1.1, 10.1.2.1, 11.0.0.0
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    
    
    check the IBM Transformation Extender Release Notes page:
    https://www.ibm.com/support/docview.wss?uid=swg27008337
    
    If the service pack or product release is available, download it
    
    
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    
    
    Interim Fix (LAIF) by opening a case:
    https://www.ibm.com/mysupport/
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH59960

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A12

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-02-22

  • Closed date

    2024-05-07

  • Last modified date

    2024-09-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A12"}]

Document Information

Modified date: