A fix is available
APAR status
Closed as program error.
Error description
Starting from CICS TS 5.6, module DFHQRCPU has been link-edited as AC(1), which requires APF authorization. However, this module is stored in SDFHLOAD library, which doesn't need to be APF-authorized.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: DFHQRCPU Link-edited as AC(1). * **************************************************************** DFHQRCPU is link-edited as AC(1) but placed in data set SDFHLOAD. It does not need to be link-edited as AC(1).
Problem conclusion
DFHQRCPU has been re-shipped and new JCLIN is provided which specifies AC(0).
Temporary fix
Comments
APAR Information
APAR number
PH59769
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
300
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-13
Closed date
2024-03-22
Last modified date
2024-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DFHQRCPU
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R300 PSY UI96197
UP24/04/03 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.