IBM Support

PH59445: DFHSM0002 ON A DISCARD FOR A PIPELINE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A discard for a pipelines creates the following error message:
    +DFHSM0002 A severe error (code X'0305') has occurred in module
    DFHSMGF.
    

Local fix

  • restart the CICS region
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: DISCARD PIPELINE may cause message      *
    *                      DFHSM0002 (code x'0305') to be issued.  *
    ****************************************************************
    A SOAP XML web service has been installed and when the
    WEBSERVICE is discarded DFHPIWR attempts to FREEMAIN the copy of
    the ICM data that would only be created for JSON services.
    This is due to residual data which when used as the address and
    length for the FREEMAIN results in message
    DFHSM0002 (code x'0305') being issued.
    

Problem conclusion

  • DFHPIWR has been changed to only FREEMAIN the copy of ICM data
    if it was originally created.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH59445

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-01-29

  • Closed date

    2024-10-24

  • Last modified date

    2024-11-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI98862 UI98863

Modules/Macros

  • DFHPIWR
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UI98862

       UP24/10/25 P F410

  • R500 PSY UI98863

       UP24/10/25 P F410

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
03 November 2024