Error description

  • Request to change the SDATA specification for the SDUMP in
    CSQWDSDM to additionally include RGN to fix the above the bar
    storage missing in the dump file.
    
    The dump looks truncated, but  IP STATUS for each dump shows:
    ==> FLAGS SET IN SDUSDATA:
     Dump all PSAs.
     Dump SQA.
     Dump LSQA.
     Dump trace data.
     Dump CSA.
     Dump summary dump data.
    
    
    Which is suspiciously missing 'Dump rgn-private area'. The
    SDUMP in CSQWDSDM which took this dump does not specify
    SDATA=RGN so whether the private region is dumped or not will
    depend on the installation defaults.
    

Local fix

  • Specify SDATA=RGN for the SDUMP in CSQWDSDM.
    This can be validated by checking the SDUMP output of /D
    DUMP,OPTIONS to see whether RGN is included in the list
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM MQ for z/OS Version 9       *
    *                 Release 2 Modification 0,                    *
    *                 Release 3 Modification 0, and                *
    *                 Release 4 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: CSQWDSDM may not collect above-the-bar  *
    *                      storage as it does not explicitly       *
    *                      request RGN so it falls on the          *
    *                      installations defaults. The default is  *
    *                      to include RGN, but it can be turned    *
    *                      off. In cases it has been turned off,   *
    *                      above-the-bar storage is not collected  *
    *                      in the dump.                            *
    ****************************************************************
    The SDUMPX SDATA specification in CSQWDSDM did not specify RGN,
    meaning that it would fall back on the installation defaults.
    
    In the case that RGN was switched off on the installation,
    above-the-bar storage would not be collected by the dump which
    is needed to diagnose and resolve problems.
    

Problem conclusion

  • The SDUMPX SDATA specification in CSQWDSDM has been updated to
    include RGN as well as NUC, LPA and TRT.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH59294

  • Reported component name

    IBM MQ Z/OS V9

  • Reported component ID

    5655MQ900

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-01-19

  • Closed date

    2024-08-19

  • Last modified date

    2024-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI98068 UI98069 UI98070

Modules/Macros

  • CSQWDSDM
    

Fix information

  • Fixed component name

    IBM MQ Z/OS V9

  • Fixed component ID

    5655MQ900

Applicable component levels

  • R200 PSY UI98070

       UP24/09/25 P F409

  • R300 PSY UI98069

       UP24/09/25 P F409

  • R400 PSY UI98068

       UP24/09/25 P F409

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"200","Line of Business":{"code":"LOB67","label":"IT Automation \u0026 App Modernization"}}]