IBM Support

PH59222: FIX IMS HALDB TOOLKIT ISSUES FOUND IN INTERNAL TESTING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR fixes several IMS HALDB Toolkit issues that were
    found in internal testing.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS HALDB Toolkit 1.1.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR fixes several IMS HALDB       *
    *                      Toolkit issues that were found in       *
    *                      internal testing.                       *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes the following issues of IBM IMS HALDB Toolkit
    V1.1.
    1. Storage shortage may occur during HTK execution when DBDs
       containing large amounts of metadata are used in an
       IMS-managed ACB environment.
       The IMS catalog API (DFS3CATQ) loads DBDs with large amounts
       of metadata below the 16MB line in an IMS managed ACB
       environment, resulting in storage shortages.
       Code has been changed to specify the new DFS3CATQ parameter
       EXTATTR=NONE, as provided in IMS APAR PH39492.
       If EXTATTR=NONE is specified, DBDs without metadata will be
       loaded.
    
    2. HTK can occasionally get ABENDS878-10 with GETMAIN processing
       of buffers when the all following conditions are met.
        1) ONLINE(Y) is specified in IHCSYSIN.
        2) BMP application updates the database in the Copy phase.
        3) IMS OSAM database
        4) DBDS block size is large.
        Code has been changed to reduce number of database buffers
        when updating OSAM database in the Copy phase.
    
    3. When dynalloc failure occurred for the restart data set,
       only the first job that allocated the restart data set
       is included in the messages in MSGPRINT DD and traces
       in TRACE DD. However when multiple jobs allocated the restart
       data set, it is better to include all job names in traces to
       make it easier to investigate.
    

Problem conclusion

  • Code has been changed to fix the issues described in this APAR.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH59222

  • Reported component name

    IMS HALDB TOOLK

  • Reported component ID

    5655DBU01

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-01-16

  • Closed date

    2024-01-24

  • Last modified date

    2024-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI95392

Modules/Macros

  • IHCULEV0 IHCWRUPD IHCWTDBG IHCXALLO IHCXIDCA IHCXSQWR IHCXUPDT
    IHCYDBDQ IHCYMSGL IHCYMSGT
    

Fix information

  • Fixed component name

    IMS HALDB TOOLK

  • Fixed component ID

    5655DBU01

Applicable component levels

  • R110 PSY UI95392

       UP24/01/27 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBQAP","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]

Document Information

Modified date: