APAR status
Closed as program error.
Error description
IHS should enable HEAPPOOLS/HEAPPOOLS64 LE option by default in new instances. It is especially useful in multi-threaded System SSL usage.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM HTTP Server on z/OS * **************************************************************** * PROBLEM DESCRIPTION: IHS may have very poor performance with * * SSL enabled when ICSF is using software * * emulation instead of CPACF * **************************************************************** * RECOMMENDATION: * **************************************************************** ICSF without CPACF makes frequent heap allocations. When being driven by multi-threaded IHS, it can result in latch contention and poor performance (high CPU, handshake delays).
Problem conclusion
New instances of IHS will have the following in bin/envvars: ``` # PH59165 enable HEAPPOOLS/HEAPPOOLS64 in new instances export _CEE_RUNOPTS="$_CEE_RUNOPTS HEAPPOOLS(ON) HP64(ON)" ``` No change is applied to existing instances. The fix for this APAR is targeted for inclusion in IBM HTTP Server fix packs 8.5.5.26 and 9.0.5.19. For more information, see 'Recommended Updates for WebSphere Application Server': https://www.ibm.com/support/pages/node/715553
Temporary fix
Comments
APAR Information
APAR number
PH59165
Reported component name
WAS IHS ZOS
Reported component ID
5655I3510
Reported release
90P
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-01-12
Closed date
2024-01-18
Last modified date
2024-01-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WAS IHS ZOS
Fixed component ID
5655I3510
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"90P","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
22 January 2024