IBM Support

PH59143: HPPC OPTIONS SPECIFIED IN ADD PC DO NOT WORK CORRECTLY IN HPPC

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When recovering FF DB with indexes by specifying ADD IB and PC,
    HPPC options specified in ADD PC do not work correctly in HPPC.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS Recovery Solution Pack for z/OS      *
    *                 Version 2 Release 1 ( FMID=HAHM210 )         *
    *                 IMS Database Recovery Facility users.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: When recovering FF DB with indexes by   *
    *                      specifying ADD IB and PC, HPPC options  *
    *                      specified in ADD PC do not work         *
    *                      correctly in HPPC.                      *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    In the case of creating an index DB by Index Builder by
    specifying ADD IB at the time of recovery of FF DB with index
    (e.g. HIDAM), when ADD PC is also specified and HPPC is also
    started, there is an issue that HPPC options specified in ADD PC
    or UTILGBL are not correctly passed to HPPC.
    The reason is that there is a problem in the process where DRF
    generates PROCCTL statements for HPPC in response to the
    specified HPPC options, and the specified HPPC options are
    enabled for the index DB instead of the main DB.
    Therefore, for example, even if the HPPC option BITMAP(NO) is
    specified in ADD PC to reduce the volume of HPPC reports, the
    option is not enabled for the main DB and BITMAP reports are
    output. As a result, ABNED SB37 may occur with STATIPRT DD for
    HPPC reports.
    

Problem conclusion

  • FRXVSTA3 is changed to correctly generate HPPC PROCCTL
    statements in response to HPPC options specified in ADD PC or
    UTILGBL, even in cases where ADD IB is specified and an index DB
    is created by Index Builder.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH59143

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-01-11

  • Closed date

    2024-01-26

  • Last modified date

    2024-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI95424

Modules/Macros

  • FRXVSTA3
    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R210 PSY UI95424

       UP24/01/27 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"210"}]