A fix is available
APAR status
Closed as program error.
Error description
S0C4 ABEND possible if STORAGE OBTAIN returns "dirty" memory for filter DSA area
Local fix
NA
Problem summary
V10.1.3-S0C4 ABEND possible if STORAGE OBTAIN returns "dirty" memory for filter DSA area
Problem conclusion
A S0C4 abend is possible if the z/OS STORAGE OBTAIN CHECKZERO=YES service call returns memory that is not "clean'. The error can occur as we are in 64bity mode during the manual clear of the memory and not all of the registers have their high order bits turned off.
Temporary fix
Comments
APAR Information
APAR number
PH59015
Reported component name
SEC GUAR STAP I
Reported component ID
5655STM00
Reported release
A13
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-01-04
Closed date
2024-01-26
Last modified date
2024-07-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI95444
Modules/Macros
AUICPY4E AUICPY4F AUIDLA0E AUIDLA0F
Fix information
Fixed component name
SEC GUAR STAP I
Fixed component ID
5655STM00
Applicable component levels
RA13 PSY UI95444
UP24/01/31 P F401
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A13","Line of Business":{"code":"LOB24","label":"Security Software"}}]
Document Information
Modified date: