IBM Support

PH58632: DFS7438E SEQUENCE NUMBER ERROR ON TPIPE=TXXXX MEMBER=MQ

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DFS7438E SEQUENCE NUMBER ERROR ON TPIPE=XXXXX MEMBER=MQ
    can be received after installation of PH52141 if IMS
    Shared Queues are used with MQ OTMA Client
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IMS 15 customers using OTMA FASTTPCU function.               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When OTMA FASTTPCU is activated with MQ Series tpipe in      *
    * shared queues, the MQ Series tpipe is incorrectly deleted    *
    * after two checkpoints. The MQ Series tpipe should always be  *
    * active, even after IMS is checkpointed. After the MQ Series  *
    * tpipe is down due to FASTTPCU error, the customer tries to   *
    * continue to use the tpipe, which caused the "DFS7438E        *
    * SEQUENCE NUMBER ERROR ON TPIPE=XXXXX MEMBER=MQ. TPIPE HAS    *
    * BEEN STOPPED" error.                                         *
    *                                                              *
    * Additional keywords: MSGDFS7438E                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * INSTALL CORRECTIVE SERVICE FOR APAR/PTF                      *
    ****************************************************************
    

Problem conclusion

  • OTMA module DFSYCKP0 was enhanced so that the FASTTPCU checking
    for MQ Series tpipe in shared queues will not bring the tpipe
    down.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58632

  • Reported component name

    IMS V15

  • Reported component ID

    5635A0600

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-12-07

  • Closed date

    2024-03-26

  • Last modified date

    2024-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI96255

Modules/Macros

  • DFSYCKP0
    

Fix information

  • Fixed component name

    IMS V15

  • Fixed component ID

    5635A0600

Applicable component levels

  • R500 PSY UI96255

       UP24/04/03 P F404

Fix is available