A fix is available
APAR status
Closed as program error.
Error description
Query Monitor shared storage initialization phase the ENQ remains permanent. Other symptoms include Query Monitor monitoring agent for a DB2 not completing due to high CPU.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Guardium STAP for Db2 * **************************************************************** * PROBLEM DESCRIPTION: 1. S-TAP START UP HUNG ON ENQ CQMXFMID * * Other symptoms include Query Monitor * * monitoring agent for a DB2 not * * completing due to high CPU * * 2. S-TAP not working with implicit * * close of cursors * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** 1. An S-TAP start-up stalled due to permanently waiting on a Query Monitor for DB2 monitoring agent install to complete. If something were to go wrong in the Query Monitor shared storage initialization phase the ENQ remains permanent 2. S-TAP missing a change event after a read event with implicit close which fails the policy
Problem conclusion
1. When the storage initialization issue is detected, changes were made to ensure the process fails so the CQM caller can adequately report the error and remove outstanding ENQs 2. Ensure S-TAP recognizes cursors that are closed implicitly.
Temporary fix
Comments
APAR Information
APAR number
PH58383
Reported component name
COMMON COLLECTO
Reported component ID
5639OLC00
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-11-27
Closed date
2023-12-26
Last modified date
2024-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQC#REST CQCISMPX CQCMCLC5 CQCMCLD5 CQCMESC5 CQCMESD5 CQCMSTRM CQCOXGC5 CQCOXGD5
Fix information
Fixed component name
COMMON COLLECTO
Fixed component ID
5639OLC00
Applicable component levels
R110 PSY UI95068
UP23/12/29 P F312
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: