IBM Support

PH58376: LIU UNDER IMS ADMINISTRATION TOOL AND CATALOG MANAGER CAUSE THE PROBLEMS WHEN THESE PROCESS UNEXPECTED INPUT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • LIU under IMS Administration Tool may cause ABEND0C4 when LIU is
    called to put the value for IMS SPUFI and LIU cannot read a DBD
    which is referred by a processing PSB. LIU under IMS
    Administration Tool and the Catalog Manager also cause BLDL
    error when LIU decodes or compares PSB and all of the following
    conditions met. The PSB is in the IMS directory staging dataset,
    the PSB has DB PCB of MSDB and the MSDB is not in the IMS
    directory staging dataset. LIU tries to obtain SENSEG value from
    MSDB and it causes BLDL error.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    *                 Version 2 Release 2 (FMID=H27P220) users     *
    *                 who use the Catalog Manager utility, the     *
    *                 LIU under the IMS Administration Tool.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: LIU under IMS Administration Tool       *
    *                      causes ABEND0C4 when LIU is called to   *
    *                      expand the PSB information for IMS      *
    *                      SPUFI and LIU cannot read a DBD which   *
    *                      is referred by a processing PSB.        *
    *                      The Catalog Manager and LIU under IMS   *
    *                      Administration Tool also cause BLDL     *
    *                      error when LIU decodes or compares      *
    *                      PSB and all of the following            *
    *                      conditions met. The PSB is in the IMS   *
    *                      directory staging dataset, the PSB has  *
    *                      DB PCB of MSDB and the MSDB is not in   *
    *                      the IMS directory staging dataset.      *
    *                      LIU tries to obtain SENSEG value from   *
    *                      MSDB and it causes BLDL error.          *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes the following issues.
    -LIU under the IMS Administration Tool causes ABEND0C4 when LIU
    is called to expand the PSB information for IMS SPUFI and LIU
    cannot read a DBD which is referred by a processing PSB. LIU is
    fixed not to cause ABSEND0C4 and it issues warning message
    MSGFABX0014W.
    -The Catalog Manager and LIU under the IMS Administration Tool
    cause BLDL error when LIU decodes or compares PSB and all of
    the following conditions met.
     - The PSB is in the IMS directory staging dataset
     - The PSB has a DB PCB of MSDB
     - The MSDB is only in the IMS directory active dataset and is
       not in the IMS directory staging dataset.
    LIU tries to read the MSDB in the IMS directory staging dataset
    to decode the SENSEG statement but LIU fails to read it and
    BLDL error is occurred.
    This APAR fixes the LIU not to cause BLDL error for processing
    a PSB in the IMS directory staging dataset. LIU issues new
    message MSGFABN0087W and decodes PSB without the SENSEG
    statement for DB PCB for MSDB.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IBM IMS Library Integrity Utilities for z/OS V2R2 User's Guide
    (SC19-3979)
    Refer to topic "What's new in IMS Library Integrity Utilities"
    (https://www.ibm.com/docs/en/ims-liu/2.2
    ?topic=overview-whats-new-in-ims-library-integrity-utilities)
    in IBM Documentation for doc changes associated with this APAR.
    

Problem conclusion

  • The following modules and macros have been modified.
    FABNMSGS, FABNPCNE, FABNPCNF, FABNPCTL, FABXAAC1, FABXAPI0,
    FABXCAP5, FABXCATM, FABXWMT, FABLMSG, FABNDMY0, FABNDST0,
    FABXCTB
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58376

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-27

  • Closed date

    2024-01-11

  • Last modified date

    2024-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI95181

Modules/Macros

  • FABNMSGS FABNPCNE FABNPCNF FABNPCTL FABXAAC1 FABXAPI0 FABXCAP5
    FABXCATM FABXWMT
    

Publications Referenced
SC19397911    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R220 PSY UI95181

       UP24/01/14 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date:
01 February 2024