APAR status
Closed as program error.
Error description
Invalid 277CA with spaces is generated by HIPAA Compliance Check when the Procedure Code in the Service Loop (SV1, SV2, SV3) contains only Pad Characters.
Local fix
ITXCQ - ITX00062193 MG / MG Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender Pack for Healthcare HIPAA Problem Description: Compliance check not producing a valid 277CA ack if procedure code in service loop (SV1, SV2, SV3) contains only pad characters. Platforms Affected: ALL
Problem conclusion
If subelement procedure code (SV10102 in 837P, SV20202 in 837I, SV30102) was not present, we generated an SVC in the 277CA with XXXXXXX so 277CA was valid. We have corrected the compliance check and hipaa_data_compliance maps to also generate this if the input subelements are all pad characters. Applies to: Healthcare Pack HIPAA 10.1.0, 10.2.0, 10.2.1, 10.2.2. Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/t ransformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH58331
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-11-22
Closed date
2023-12-20
Last modified date
2023-12-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]
Document Information
Modified date:
28 December 2023