IBM Support

PH58313: CHANGE IN TRIGGER EXECUTION ORDER IS NOT DETECTED IN CM ANALYZE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When Compare in CMDELTA mode generates drop/create for trigger
    to maintain execution order and table for these triggers in not
    changed, CM Analyze will not detect trigger execution order
    change and report 'No changes' for triggers.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Administration Tool for z/OS    *
    ****************************************************************
    * PROBLEM DESCRIPTION: When Change Management is used to       *
    *                      change trigger execution order, this    *
    *                      change cannot be detected if no change  *
    *                      exists for the table.                   *
    ****************************************************************
    Change to the trigger execution order requires a drop and create
    for triggers. But if the table is not included in the Compare
    scope by Change Management, this change is not detected and
    triggers are reported as objects with 'No changes'.
    

Problem conclusion

  • The problem has been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58313

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-21

  • Closed date

    2024-02-26

  • Last modified date

    2024-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI95811 UI95812

Modules/Macros

  • ADBCVOC
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI95811

       UP24/02/29 P F402

  • RD10 PSY UI95812

       UP24/02/29 P F402

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: