IBM Support

PH58167: OUTPUT FROM WDI AND ITX ARE DIFFERENT FOR EDI COMPLIANCE 'DATA ELEMENT POSITION IN SEGMENT' USING EDIFACT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using the IBM Transformation Extender Pack for Supply Chain
    EDI 10.2.1.0 with EDI data and processing input containing the
    following example BGM segment.
    
    Input:'BGM+1234+2023072617770001'
    
    E2098 One or more segments in the transaction are in error.
    E2058 The segment at position 2, segment id 'BGM' contains data
    element errors.
    E2139 An element is too long. Element: 1, Subelement: 1,
    Occurrence: n/a, Value: '1234'
    
    Output from WDI and ITX are different.
    
    WDI Output: UCD+39+2:1
    ITX Output: UCD+39+1:1
    
    Erroneous Data Element Position in Segment (0098) Identifies by
    numerical location, within a segment, the single or composite
    element containing the error. The segment mark must always be
    considered number one (1).
    

Local fix

  • ITXCQ - ITX00062186
    PB / PB
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender Pack for Supply Chain EDIFACT
    compliance check
    
    Problem Description:
    Output from WDI and ITX there is inconsistency between
    "Erroneous data element position in segment" using EDI
    Compliance.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • The element position is off by 1 and is not counting the segment
     identifier as first position.
    
    Applies to:
    Supply Chain Pack EDIFACT 10.2.2.
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Downloads page:
    http://www.ibm.com/support/entry/portal/product/other_software/t
    ransformation_extender
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a PMR:
    http://www.ibm.com/support/servicerequest/Home.action
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58167

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-14

  • Closed date

    2023-12-20

  • Last modified date

    2025-04-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date:
10 April 2025