A fix is available
APAR status
Closed as program error.
Error description
When CDC z/OS is configured to replicate LOB column, even the LOB data is inserted with non-empty value, under some rare conditions, CDC z/OS source engine may send an empty LOB value to the target, this causes the LOB data loss.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IIDR CDC for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: When the Db2 for z/OS SKIPUNCI * * subsystem parameter is set to YES,it is * * possible to miss the LOB data for any * * SQL activity that changes the source * * table during refresh activity. * **************************************************************** LOB data may be replicated as empty when SKIPUNCI Db2 parameter is set to YES.
Problem conclusion
The WAITFOROUTCOME parameter for Db2 for z/OS is used to make sure that uncommitted LOBs are not sent as empty data during the refresh activity. These issues may occur only during the refresh activity. Hence, changes to the refresh process correct both of them.
Temporary fix
Comments
APAR Information
APAR number
PH58141
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-11-13
Closed date
2025-05-08
Last modified date
2025-05-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CHCBNDPL CHCDSCPF CHCDTRD8 CHCDTRDB CHCPAAUT
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UO02914
UP25/05/09 I 1000
Fix is available