IBM Support

PH58141: IIDR CDC FOR Z/OS MAY REPLICATE SOURCE NON-EMPTY LOB DATA TO TARGET AS EMPTY.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When CDC z/OS is configured to replicate LOB column, even the
    LOB data is inserted with non-empty value, under some rare
    conditions, CDC z/OS source engine may send an empty LOB value
    to the target, this causes the LOB data loss.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IIDR CDC for z/OS.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the Db2 for z/OS SKIPUNCI          *
    *                      subsystem parameter is set to YES,it is *
    *                      possible to miss the LOB data for any   *
    *                      SQL activity that changes the source    *
    *                      table during refresh activity.          *
    ****************************************************************
    LOB data may be replicated as empty when SKIPUNCI Db2 parameter
    is set to YES.
    

Problem conclusion

  • The WAITFOROUTCOME parameter for Db2 for z/OS is used to make
    sure that uncommitted LOBs are not sent as empty data during
    the refresh activity.
    
    These issues may occur only during the refresh activity.
    Hence, changes to the refresh process correct both of them.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58141

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-13

  • Closed date

    2025-05-08

  • Last modified date

    2025-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CHCBNDPL CHCDSCPF CHCDTRD8 CHCDTRDB CHCPAAUT
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UO02914

       UP25/05/09 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Line of Business":{"code":"LOB76","label":"Data Platform"}}]

Document Information

Modified date: