Error description
Customer is using the AFFINITY ODPP provider in a Column Map (CM). When the data contains MIXED or GRAPHIC DBCS data, or data with DB2 substitution characters, the process aborts with a System Error: IBM InfoSphere Optim System Error Structure - ErrCB ErrCB.ID : ZZZERRCBZZ SysRel : 11.7.0 DB2Rel : 1215(NFM) ErrCB.Type : SYSTEM_ERROR ErrCB.AuxInfo : ErrCB.Code : -1 ErrCB.U.Msg : Src 8BDB0020 pos 1 cannot be translated. or ErrCB.U.Msg : Src 3F3F4040 pos 15 cannot be translated. Number of Function Entries= 11 ErrCB.N(0).Src= FOPLBRDP 20230220 PH52040 ErrCB.N(0).Func= (001846) ProcessRowODPP
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Optim users performing CM processing using * * ODPP AFFINITY providers directly from the CM * * (without a CM PROC/Lua). * **************************************************************** * PROBLEM DESCRIPTION: See Error Description. * **************************************************************** 1. Optim performs internal data conversions while interfacing with the ODPP AFFINITY provider. While conversion errors are being detected the process is being aborted instead of being continued. 2. Optim performs internal data conversions while interfacing with the ODPP AFFINITY provider. In some scenarios (MIXED or GRAPHIC DBCS data) such conversions may not be necessary which would avoid causing conversion errors.
Problem conclusion
The program logic has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PH58041
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-11-07
Closed date
2023-11-17
Last modified date
2023-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FOP1ODRV FOP4PEMN FOP4TRCE FOPCFPMN FOPHSTM FOPMAIN FOPMAMAI FOPMCENU FOPMCMAI FOPMCOLA FOPMCOLP FOPMDPRC FOPMDXTR FOPMECMN FOPMEMAI FOPMMCMR FOPMMJBS FOPMSELM FOPODPP FOPOMN FOPRS10 FOPZFBMN FOPZFMMN
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI94530
UP23/11/18 P F311
Fix is available