IBM Support

PH57182: IF THE DB2 LOAD UTILITY BATCH JOB FAILS DUE TO JCL OR SECURITY ISSUE, IIDR CDC FOR DB2 Z/OS APPLY TASK MAY SUSPEND INDEFINITELY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When DB2 LOAD Utility is engaged to apply data during refresh
    but the batch job fails due to JCL or security issue, before the
    time specified in LOADTIMEOUT parameter expires, if a SHUTDOWN
    command is issued to bring down the CDC z/OS address space, the
    apply task would suspend indefinitely and stop the address space
    from shutting down, even SHUTDOWN,ABORT is used.
    

Local fix

  • Cancel the CDC z/OS address space.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IIDR CDC for z/OS                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: When DB2 LOAD Utility is engaged to     *
    *                      apply data during refresh but the batch *
    *                      job fails due to JCL or security issue, *
    *                      before the time specified in            *
    *                      LOADTIMEOUT parameter expires, if a     *
    *                      SHUTDOWN command is issued to bring     *
    *                      down the CDC z/OS address space, the    *
    *                      apply task would suspend indefinitely   *
    *                      and stop the address space from         *
    *                      shutting down, even SHUTDOWN,ABORT is   *
    *                      used.                                   *
    ****************************************************************
    CDC z/OS fails to reset the Load Utility Job Submitted indicator
    when such batch job is not submitted successfully and an address
    space shutdown command is issued before Load Utility job timeout
    logic resets it, this causes the shutdown process to be stuck.
    

Problem conclusion

  • The related logic has been corrected to reset the Load Utility
    Job Submitted indicator in above described situation.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH57182

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-09-27

  • Closed date

    2023-10-16

  • Last modified date

    2023-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI94014

Modules/Macros

  • CHCDTCLD CHCLDRMN
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI94014

       UP23/11/11 P F311

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 December 2023